QRS Music Technologies Ancho Installation Manual Page 52

  • Download
  • Add to my manuals
  • Print
  • Page
    / 68
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 51
Ancho
PAGE 52
QRS MUSIC TECHNOLOGIES
Ancho V69_1
Restoring The Factory Default Settings
Remove the CompactFlash card and CDROM disc before proceeding! Power Ancho OFF.
Press and Hold the SELect button while powering Ancho ON.
When “QRS MUSIC TECHNOLOGIES” appears Count 2 Seconds then release the SELect button.
“System Configuration” displays and then Ancho will then go through the normal turn on sequence.
Rotate the ADJust dial to move the arrow to the center of the display until “SETUP” displays.
Press the SELect button to enter the “System Configuration” Setup Menu.
Rotate the ADJust dial to move the arrow to the far right of the display, pointing toward “Ex”.
Press the SELect button to execute and reset the default settings.
Quickly press the SELect button twice, within one-half second, to exit the Setup Menu.
S y s t e m C o n f i g u r a t i o n
0 2 4
m
I N
S E T U P
V 0 6 4
S Y S Y E M D e f l t s E x
S Y S Y E M D e f l t s E x
R E S E T D E F A U L T S ( S c c )
Restoring
Restoring The Application Image
The Application Image file (appl.ima) holds the program code, or operating system, for the Ancho controller’s user function set. It
allows the user to operate the Pianomation player piano system using all of Petine’s functions and settings. The System Image file
(syst.ima) holds the “core” program code for Petine. If the Application Image ever becomes corrupted or unusable for any reason,
the System Image serves as a “backup” and allows the user to re-load or “restore” the Application Image.
If your Ancho unit powers on in the following sequence then an update is required to restore the system.
Download the current Application Inage “Appl.ima” file from the QRS website [http://www.qrsmusic.com/support_pa.asp] and
copy it to a RW type CD-ROM or CompactFlash card.
Insert the CD-ROM or CompactFlash card containing the Appl.ima file and follow the instructions below.
Press the SELect button.
Ancho will search for the update file.
Successful update. Power OFF and ON again.
A n c h o C D S n :
S y s t e m C h e c k . . . .
E r r = 8 0 , p r e s s E n t e r
I n s e r t a C D - R O M D i s k
S y s t e m C h e c k U s r
E r r = 8 0 , p r e s s E n t e r
D e t e c t C D R O M / C F L A S H
U P G / F M T : S U C C E S S !